N5224A 43G參數指標N5224A
N5224A PNA 微波網絡分析儀,43.5 GHz
-
N5224A 43G參數指標N5224A
-
獲得測量和設計成果
-
PNA 提供出色的測量完整性,可將深入的洞察轉變為出色的設計
-
使用性能出眾的微波網絡分析儀,應對苛刻的測量挑戰
-
是德科技 S 參數測量有很高的精度
-
通過個性化配置得到恰當的性能,以滿足您特定的預算和測量需求
N5224A 43G參數指標N5224A包括的內容:
-
插頭、孔、底腳
-
安裝和快速入門指南
-
安全手冊
-
校準證書
-
3 個電感器(磁芯)
-
扳手
-
束線帶
-
光學鼠標

N5224A 10 MHz to 43.5 GHz N5225A 10 MHz to 50 GHz
N5232A PNA-L 微波網絡分析儀,20 GHz
N5231A PNA-L 微波網絡分析儀,13.5 GHz
N5230A PNA-L 網絡分析儀, 2 端口,高達 6, 13.5, 20, 40, 或 50 GHz網絡分析儀
網絡分析儀
N5231B PNA-L 微波網絡分析儀,13.5 GHz
網絡分析儀
N5234B PNA-L 微波網絡分析儀,43.5 GHz
網絡分析儀
N5235B PNA-L 微波網絡分析儀,50 GHz
N5232B PNA-L 微波網絡分析儀,20 GHz
PNA系列網絡分析儀:
E8362B PNA 系列網絡分析儀,10 MHz 至 20 GHz
E8363B PNA 系列網絡分析儀, 10 MHz至 40 GHz
E8364B PNA 系列網絡分析儀, 10 MHz 至 50 GHz
E8362A FNA 系列網絡分析儀,45 MHz 至 20 GHz
E8363A PNA 系列網絡分析儀,45 MHz 至 40 GHz
E8364A PNA 系列網絡分析儀,45 MHz 至 50 GHz
E8361A PNA 系列網絡分析儀,45 MHz 至 67G GHz
E8362C PNA 微波網絡分析儀
E8363C PNA 微波網絡分析儀
E8364C PNA 微波網絡分析儀
E8361C PNA 微波網絡分析儀
Keysight PNA微波網絡分析儀
N5222A 10 MHz - 26.5 GHz
N5224A 10 MHz - 43.5 GHz
N5225A 10 MHz - 50 GHz
N5227A 10MHZ-67GHZ
E8361C 10MHZ-67GHZ
E8361A 10 MHz - 67 GHz
N5224B PNA 微波網絡分析儀,900 Hz/10 MHz 至 43.5 GHz
N5224B 10 MHz 至 43.5 GHz,1 個信號源 2 端口和 2 個信號源 4 端口、信號源和接收機衰減器、偏置 T 型接頭、脈沖發生器和調制器、噪聲系數射頻性能.
N5224B HIGHLIGHTS
-
N5224A 43G參數指標N5224A
-
使用性能出眾的微波網絡分析儀,應對苛刻的測量挑戰
-
在測量 S 參數時實現超低的不確定度和超高穩定度
-
利用應用軟件簡化設置,高效表征有源器件
-
通過定制化配置得到恰當的性能,滿足您的特殊預算和測量需求
-
多點觸控屏和直觀的用戶界面加速對元器件特性的分析
N5224A 43G參數指標N5224A包括的內容:
-
插孔、底腳
-
安裝和快速入門指南
-
安全手冊
-
校準證書
-
3 個電感器(磁芯)
-
扳手
-
束線帶
-
光學鼠標
N5224A 43G參數指標N5224A Hardware options
|
N5224B-200
|
2-port, base hardware configuration
|
|
|
N5224B-201
|
2-port with configurable test set, reference mixer switch
|
|
|
N5224B-205
|
2-port with configurable test set, ref mixer switch, bias tees, low frequency extension
|
|
|
N5224B-210
|
2-port with metrology configuration
|
|
|
N5224B-217
|
2-port with configurable test set, reference mixer switch, source and receiver attenuators
|
|
|
N5224B-219
|
2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
|
|
|
N5224B-220
|
2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension
|
|
|
N5224B-400
|
4-port with second source
|
|
|
N5224B-401
|
4-port with second source, configurable test set, reference mixer switch
|
|
|
N5224B-405
|
4-port with second source, configurable test set, reference mixer switch, bias tees, low frequency extension
|
|
|
N5224B-410
|
4-port with second source, metrology configuration
|
|
|
N5224B-417
|
4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators
|
|
|
N5224B-419
|
4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees
|
|
|
N5224B-420
|
4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension
|
|
Calibration documentation
|
N5224B-1A7
|
Calibration + Uncertainties + Guardbanding (Not Accredited)
|
|
|
N5224B-A6J
|
ANSI Z540-1-1994 Calibration
|
|
|
N5224B-UK6
|
Commercial calibration certificate with test data
|
|
Additional hardware capability
|
N5224B-020
|
Add IF inputs
|
|
|
N5224B-021
|
Add pulse modulator to internal 1st source
|
|
|
N5224B-022
|
Add pulse modulator to internal 2nd source
|
|
|
N5224B-UNY
|
Enhanced low phase noise performance
|
|
Software with Subscription
|
S93007B
|
Automatic fixture removal
|
|
|
S93010B
|
Time-domain analysis
|
|
|
S93011B
|
Enhanced time domain analysis with TDR
|
|
|
S93015B
|
Real-time S-parameter and power measurement uncertainty
|
|
|
S93025B
|
Basic pulsed-RF measurements
|
|
|
S93026B
|
Advanced pulsed-RF measurements
|
|
|
S93029B
|
Noise figure measurements with vector correction
|
|
|
S93080B
|
Frequency-offset measurements
|
|
|
S93082B
|
Scalar mixer/converter measurements
|
|
|
S93083B
|
Vector and scalar mixer/converter measurements
|
|
|
S93084B
|
Embedded-LO capability
|
|
|
S93086B
|
Gain-compression measurements
|
|
|
S93087B
|
Intermodulation distortion measurements
|
|
|
S93088B
|
Source phase control
|
|
|
S93089B
|
Differential and I/Q device measurements
|
|
|
S930900B
|
Spectrum analysis up to 8.5 GHz
|
|
|
S930901B
|
Spectrum analysis up to 13.5 GHz
|
|
|
S930902B
|
Spectrum analysis up to 26.5 GHz
|
|
|
S930904B
|
Spectrum analysis up to 43.5 GHz
|
|
|
S930909B
|
Spectrum analysis up to 90 GHz
|
|
|
S93093B
|
Spectrum analysis to 120 GHz
|
|
|
S93094B
|
Spectrum analysis beyond 120 GHz
|
|
|
S93118B
|
Fast CW measurements
|
|
|
S93460B
|
True-mode stimulus
|
|
|
S93551B
|
N-port measurements
|
|
|
S93898B
|
Built-in performance test software
|
|
|
S930317B
|
Phase noise measurement up to 70 GHz
|
|
|
S930321B
|
Phase noise measurement up to 125 GHz
|
|
|
S94601B
|
Device measurement eXpert - DMX
|
|
|
S94602B
|
Limit assistant
|
|
|
S930700B
|
Modulation distortion up to 8.5 GHz
|
|
|
S930701B
|
Modulation distortion up to 13.5 GHz
|
|
|
S930702B
|
Modulation distortion up to 26.5 GHz
|
|
|
S930704B
|
Modulation distortion up to 43.5 GHz
|
|
Accessories
|
N5224B-1CM
|
Rack mount kit for installation without handles
|
|
|
N5224B-1CP
|
Rack mount kit for installation with handles
|
|
|
N1966A
|
Pulse/IO Adapter
|
|
|
N6171A
|
MATLAB Software
|
|
|
N5224B-SSD
|
Additional removable solid state drive
|
|