主要技術參數 |
|
|
●產品執行標準 IEC584 GB/T16839-1997 IEC1515 JB/T5518-91 GB3836 |
|
|
|
|
|
常溫絕緣電阻 |
|
|
●常溫絕緣電阻 熱電偶在環境溫度為20±15℃,相對濕度不大于80%,試驗電壓為500±50V(直流)電極與外套管之間的絕緣電阻 ≥100MΩ.m。 |
|
|
|
|
測溫范圍及允差 |
|
|
●測溫范圍及允差 |
|
|
型號 |
分度號 |
允許誤差與偶材等級 |
|
I級 |
II級 |
|
允差值 |
測溫范圍℃ |
允差值 |
測溫范圍℃ |
|
SD-WRN |
K |
±1.5℃ ±0.004│t│ |
-40~+375 375~1000 |
±2.5℃ ±0.0075│t│ |
-40~+333 333~1200 |
|
SD-WRM |
N |
±1.5℃ ±0.004│t│ |
-40~+375 375~1000 |
±2.5℃ ±0.0075│t│ |
-40~+333 333~1200 |
|
SD-WRE |
E |
±1.5℃ ±0.004│t│ |
-40~+375 375~800 |
±1.5℃ ±0.004│t│ |
-40~+333 333~900 |
|
SD-WRF |
J |
±1.5℃ ±0.004│t│ |
-40~+375 375~750 |
±1.5℃ ±0.004│t│ |
-40~+333 333~750 |
|
SD-WRC |
T |
±1.5℃ ±0.004│t│ |
-40-~+125 125~350 |
±1℃ ±0.0075│t│ |
-40~+333 133~350 |
|
SD-WRP |
S |
±1℃ ±[1+0.003(t-1100)] |
0~+1100 1100~1600 |
±2.5℃ ±0.0025│t│ |
0~600 600~1600 |
|
|
●取證一覽表 |
|
|
防爆級別 |
防爆證號 |
認證機構 |
|
dIIB T4 |
GYB96450 |
NEPSI |
|
dIIB T4 |
GYB96453 |
NEPSI |
|
dII CT5 |
GYB98339 |
NEPSI |
|
dII CT5 |
GYB97197 |
NEPSI |
|
iaIICT6 |
GYB99412 |
NEPSI |
|
注:NEPSI防爆認證系*儀器儀表防爆安全監督檢驗站。 |
|
●防爆分組形式 |
|
|
○電氣設備類別 Ⅰ類——煤礦井下用電氣設備 Ⅱ類——工廠用電氣設備 ○防爆等級 防爆熱電偶的防爆等級按其使用于爆炸性氣體混合物*大安全間隙分為A、B、C三級。 |
|
類別 |
級別 |
*大試驗安全間隙(MESG)mm |
|
II |
A |
0.9≤MESG |
|
B |
0.5<MESG<0.9 |
|
C |
MESG≤0.5 |
|
|
|
○溫度組別 防爆熱電偶的溫度組別按其外露部分允許*高表面溫度分為T1~T6。 |
|
溫度組別 |
允許*高表面溫度℃ |
|
T1 |
450 |
|
T2 |
300 |
|
T3 |
200 |
|
T4 |
135 |
|
T5 |
100 |
|
T6 |
85 |
|
●防爆級別 EXdⅡ□T□ ExiaⅡ□T□ ●防護等級:IP65 |
|
|
|
|
接線盒形式 |
|
|
|
|
型號命名方法
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SD-W |
溫度儀表 |
|
|
|
|
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
R |
熱電偶 |
|
|
|
|
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
感溫元件材料 分度號 |
|
M N E F C P Q R |
鎳鉻硅-鎳硅 N 鎳鉻-鎳硅 K 鎳鉻-銅鎳 E 鐵-銅鎳 J 銅-銅鎳 T 鉑銠10-鉑 S 鉑銠13-鉑 R 鉑銠30-鉑6 B |
|
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
偶絲對數 |
|
無 2 |
單支 雙支 |
|
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
安裝固定形式 |
|
1 2 4 5 |
無固定裝置 固定螺紋 固定法蘭 活絡管接頭式 |
|
| | | | | | | | | | | | | | | | | |
接線盒形式 |
|
4 |
防爆式 |
|
| | | | | | | | | | | | | | | | | |
保護管直徑 |
|
0 1 |
Φ16 Φ12(Φ20) |
|
| | | | | | | | | | |
工作端形式 |
|
G |
變截面 |
|
| | | | | | | | |
|
|
|
SD-W |
R |
N |
2 |
—— |
2 |
4 |
0 |
G |
典型型號示例 |
|
|
選型須知
|
|
|
1)型號 2)分度號 3)防爆等級 4)精度等級 5)安裝固定形式 6)保護管材質 7)長度或插入深度 例A:防爆熱電偶,K型,固定螺紋M27×2,隔爆等級dIIBT4級,保護管316L長度450mm,插入深度300mm。 SD-WRN-240,K,L=450×300,M27×2,dIIBT4保護管316L。 |