Suitability
for use
|
Standard
cable specially designed for fast, permanent installation
|
Used
for intrinsically safe distributed I/O systems for permanent
installation
|
For
use in chemically and mechanically demanding environments
|
For
use in the food, beverages and tobacco industries
|
|
Cable
designation
|
02YSY
(ST) CY 1x2x0,64/2,55-150 VI KF 40 FR
|
02YSY
(ST) CY 1x2x0,64/2,55 BL KF40 FR
|
02YSY
(ST) C11Y 1x2x0,64/2,55-150 VI KF 40 FR
|
02YSY
(ST) C2Y 1x2x0,64/2,55-150 KF 40
|
|
Electrical
data
|
|
|
|
|
|
Damping
ratio per length
|
|
|
|
|
|
|
2.5 dB/km
|
2.5 dB/km
|
2.5 dB/km
|
2.5 dB/km
|
|
|
4 dB/km
|
4 dB/km
|
4 dB/km
|
4 dB/km
|
|
|
22 dB/km
|
22 dB/km
|
22 dB/km
|
22 dB/km
|
|
|
42 dB/km
|
42 dB/km
|
42 dB/km
|
42 dB/km
|
|
Impedance
|
|
|
|
|
|
|
150 ?
|
150 ?
|
150 ?
|
150 ?
|
|
|
270 ?
|
270 ?
|
270 ?
|
270 ?
|
|
|
185 ?
|
185 ?
|
185 ?
|
185 ?
|
|
|
150 ?
|
150 ?
|
150 ?
|
150 ?
|
|
Relative
symmetrical tolerance
|
|
|
|
|
|
|
10 %
|
10 %
|
10 %
|
10 %
|
|
|
10 %
|
10 %
|
10 %
|
10 %
|
|
|
10 %
|
10 %
|
10 %
|
10 %
|
|
Loop
resistance per length maximum
|
110 m?/m
|
110 m?/m
|
110 m?/m
|
110 m?/m
|
|
Shield
resistance per length maximum
|
9.5 ?/km
|
9.5 ?/km
|
9.5 ?/km
|
9.5 ?/km
|
|
Insulation
resistance coefficient
|
|
16 000 G?·m
|
|
|
|
Capacity
per length at 1 kHz
|
28.5 pF/m
|
28.5 pF/m
|
28.5 pF/m
|
28.5 pF/m
|
|
Operating
voltage
|
|
|
|
|
|
|
100 V
|
80 V
|
80 V
|
80 V
|
|
Mechanical
data
|
|
|
|
|
|
Number
of electrical cores
|
2
|
2
|
2
|
2
|
|
Design
of the shield
|
Overlapped
aluminum-clad foil, sheathed in a braided screen of tin-plated copper
wires
|
Overlapped
aluminum-clad foil, sheathed in a braided screen of tin-plated copper
wires
|
Overlapped
aluminum-clad foil, sheathed in a braided screen of tin-plated copper
wires
|
Overlapped
aluminum-clad foil, sheathed in a braided screen of tin-plated copper
wires
|
|
Type
of electrical connection FastConnect
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Core
diameter
|
|
|
|
|
|
|
|
0.64 mm
|
|
|
|
Outer
diameter
|
|
|
|
|
|
|
0.65 mm
|
0.64 mm
|
0.65 mm
|
0.65 mm
|
|
|
2.55 mm
|
2.55 mm
|
2.55 mm
|
2.55 mm
|
|
|
5.4 mm
|
5.4 mm
|
5.4 mm
|
5.4 mm
|
|
|
8 mm
|
8 mm
|
8 mm
|
8 mm
|
|
Symmetrical
tolerance of the outer diameter of cable sheath
|
0.4 mm
|
0.4 mm
|
0.4 mm
|
0.4 mm
|
|
Material
|
|
|
|
|
|
|
PE
|
PE
|
PE
|
PE
|
|
|
PVC
|
PVC
|
PVC
|
PVC
|
|
|
PVC
|
PVC
|
PUR
(TPE-U)
|
PE;
Outer cover made of PE is especially suitable for the food processing
industry
|
|
Color
|
|
|
|
|
|
|
red/green
|
red/green
|
red/green
|
red/green
|
|
|
Violet
|
blue
|
Violet
|
Black
|
|
Bending
radius
|
|
|
|
|
|
|
37.5 mm
|
37.5 mm
|
75 mm
|
30 mm
|
|
|
75 mm
|
75 mm
|
150 mm
|
60 mm
|
|
Tensile
load maximum
|
100 N
|
100 N
|
100 N
|
100 N
|
|
Weight
per length
|
80 kg/km
|
80 kg/km
|
71 kg/km
|
67 kg/km
|
|
Permitted
ambient conditions
|
|
|
|
|
|
Ambient
temperature
|
|
|
|
|
|
|
-40 ... +75 °C
|
-40 ... +75 °C
|
-40 ... +60 °C
|
-40 ... +60 °C
|
|
|
-40 ... +75 °C
|
-40 ... +75 °C
|
-40 ... +60 °C
|
-40 ... +60 °C
|
|
|
-40 ... +75 °C
|
-40 ... +75 °C
|
-40 ... +60 °C
|
-40 ... +60 °C
|
|
|
-40 ... +75 °C
|
-40 ... +75 °C
|
-40 ... +60 °C
|
-40 ... +60 °C
|
|
|
Electrical
properties measured at 20 °C, tests according to DIN 47250 part 4 respectively
DIN VDE 0472
|
Electrical
properties measured at 20 °C, tests according to DIN 47250 part 4 respectively
DIN VDE 0472
|
Electrical
properties measured at 20 °C, tests according to DIN 47250 part 4 respectively
DIN VDE 0472
|
Electrical
properties measured at 20 °C, tests according to DIN 47250 part 4 respectively
DIN VDE 0472
|
|
Burning
behavior
|
flame
resistant according to IEC 60332-3-24 (Category C) and UL 1685 (CSA FT
4)
|
flame
resistant according to IEC 60332-3-24 (Category C)
|
flame
resistant according to IEC 60332-1
|
inflammable
|
|
Chemical
resistance
|
|
|
|
|
|
|
oil
resistant according to IEC 60811-2-1 (4 hours / 70°C)
|
oil
resistant according to IEC 60811-2-1 (4 h / 70°C)
|
oil
resistant according to IEC 60811-2-1 (7x24h/90°C)
|
oil
resistant according to IEC 60811-2-1 (4 h / 70°C)
|
|
|
Conditional
resistance
|
Conditional
resistance
|
resistant
|
Conditional
resistance
|
|
|
conditional
resistance
|
conditional
resistance
|
conditional
resistance
|
conditional
resistance
|
|
Radiological
resistance to UV radiation
|
resistant
|
resistant
|
resistant
|
resistant
|
|
Product
properties, functions, components general
|
|
|
|
|
|
Product
feature
|
|
|
|
|
|
|
No
|
No
|
No
|
No
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Standards,
specifications, approvals
|
|
|
|
|
|
UL/ETL
listing 300 V Rating
|
Yes;
c(UL)us, CMG / CL3 / Sun Res
|
Yes;
CMG / CL3 / Sun Res
|
Yes;
c(UL)us, CMX
|
No
|
|
UL/ETL
style 600 V Rating
|
Yes
|
Yes
|
No
|
No
|
|
Certificate
of suitability
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Marine
classification association
|
|
|
|
|
|
|
No
|
No
|
No
|
No
|
|
|
No
|
No
|
No
|
No
|
|
|
No
|
No
|
No
|
No
|
|
|
No
|
No
|
No
|
No
|
|
|
No
|
No
|
No
|
No
|
|
|
No
|
No
|
No
|
No
|
|
|
No
|
No
|
No
|
No
|