TYPE
|
250 Ampere current source
|
|
PHYSICAL SPECIFICATIONS
|
16.8”W x 12.6”H x 10.6”D (42.6 cm x 32.0 cm x 27.0 cm); Weight: 46 lbs (21 kg)
|
|
INPUT POWER
|
100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz
|
|
OUTPUT CURRENTS
|
0 – 5 A @ 120 Vac max;
0 – 25 A @ 24 Vac max;
0 – 120 A @ 6 Vac max;
0 – 250 A @ 3 Vac max;
Instantaneous current: 700A
|
|
INTERNAL CURRENT METER
|
100 mA – 1000 A; Accuracy: 1% of reading ±20mA
|
|
MEASUREMENT METHOD
|
Isolated CT
|
|
EXTERNAL METER RANGE
|
10 mA – 10 A; Accuracy: 1% of reading, ±2mA
|
|
MEASUREMENT METHOD
|
Isolated CT
|
|
TIMER READING RANGE
|
1ms – 2 hours; Accuracy: 0.1% of reading ±1ms
|
|
TIMER STOP INPUTS
|
Voltage input (24V – 300V, DC or peak AC), dry contact input, or removal of primary current
|
|
DISPLAY
|
Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight and low-light levels
|
|
COMPUTER INTERFACE
|
RS-232C port for factory calibration and diagnostics
|
|
SAFETY
|
Designed to meet IEC61010 (1995), UL61010A-1, CSA-C22.2 standards
|
|
ENVIRONMENT
|
Operating: -10?C to 50? C (15?F to +122? F); Storage: -30? C to 70? C (-22?F to +158? F)
|
|
CABLES
|
Power cord, ground cable, 10-foot #2 AWG test leads
|
|
OPTIONS
|
Transportation case
|
|
WARRANTY
|
One year on parts and labor
|
|
Specifications are valid at nominal voltage and ambient temperature of +25?C (+77?F).
|