TYPE
|
portable digital circuit breaker analyzer
|
|
PHYSICAL SPECIFICATIONS
|
18.5”W x 14”H x 7”D (47.0 cm x 35.7 cm x 17.6 cm);
Weight: 20 lbs (9.1 kg)
|
|
INPUT POWER
|
3 Amps, 100 – 240 Vac, 50/60 Hz
|
|
DRY-CONTACT INPUTS
|
3 dry-contact channels; each channel detects main contact and insertion resistor contact
|
|
TIMING WINDOWS
|
1-second, 10-seconds, or 20-seconds
|
|
TIMING RESOLUTIONS
|
±50 micro-seconds @ 1-second duration, ±500 micro-seconds @ 10-second duration, ±1.00 milli-second @ 20-second duration
|
|
TIMING ACCURACY
|
0.05% of reading ±0.1 ms @ 1-second duration
|
|
CONTACT DETECTION RANGE
|
Closed: less than 20 ohms; Open: greater than 5,000 ohm
|
|
RESISTOR DETECTION RANGE
|
50 – 5,000 ohms
|
|
TRIGGER INPUT VOLTAGE
|
Open/Close: 30 – 300V, DC or peak AC
|
|
VOLTAGE SENSING INPUT RANGE
|
V1: analog input; 0 – 255V, DC or peak AC; Sensitivity: ±1V
V2: voltage presence/absence detector input; 30 – 300V, DC or peak AC
|
|
BREAKER OPERATIONS
|
Initiate Open, Close, Open – Close, Close – Open, Open – Close – Open
|
|
BREAKER INITIATE CAPACITY
|
30A, 250 Vac/dc max
|
|
INITIATE CURRENT READING RANGE
|
One, non-contact, Hall-effect sensor, 0 – 20 amp range, dc to 5Khz
|
|
TRAVEL TRANSDUCER INPUT
|
1 digital travel transducer channel; Linear range: 0.0 – 60.0 in (±0.005 in.); Rotary range: 0 – 360 degrees (±0.006 degrees)
|
|
CONTACT TRAVEL POINT DIFFERENCE
|
Measures “slow-close” contact-point distances; results can be printed
|
|
CT CURRENT SENSOR
|
One, non-contact, 0 – 100A
|
|
DISPLAY
|
Back-lit LCD screen (240 x 128 pixels); viewable in bright sunlight and low light levels
|
|
PRINTER
|
Built-in 4.5-inch wide thermal printer can print both graphic contact travel waveforms and tabulated test results
|
|
INTERNAL TEST RECORD STORAGE
|
Stores up to 200 test records and 100 test plans
|
|
COMPUTER INTERFACES
|
One USB port, optional Bluetooth interface
|
|
PC SOFTWARE
|
Windows?-based Vanguard Circuit Breaker Analysis (VCBA S2) software is included with purchase price. Software updates available at no additional charge.
|
|
SAFETY
|
Designed to meet UL/IEC 61010 and CAN/CSA C22.2 No. 1010.1-92 standards
|
|
ENVIRONMENT
|
Operating: -10°C to 50° C (15°F to +122° F); Storage: -30° C to 70° C (-22°F to +158° F)
|
|
OPTIONS
|
Transportation case (available for the DigiTMR S2 and the travel transducers)
|
|
WARRANTY
|
One year on parts and labor
|
|
Specifications are valid at nominal voltage and ambient temperature of +25?C (+77?F).
|